Unreinforced Masonry (URM) has been extensively used as a construction material in mass structures with predominant compression load paths. Despite its reasonably established performance under gravity actions, it can be quite vulnerable to seismic loading, predominantly due to its limited tensile strength and associated quasi-brittle failure modes. Therefore, a reliable seismic assessment of URM structures, including heritage buildings, is vital to ensure life safety and minimise their risk of collapse. This can assist in implementing effective remedial measures, if required, to ensure desirable performance level in future events. Despite significant advancements in masonry research, practical assessment of URM has always been a challenge for structural engineers due to the complexity of the mechanics and geometry involved. Different modelling approaches have been trialled so far, which are typically based on equivalent frame, discrete and continuum elements in 2D/3D domains. In this paper, a simplified nonlinear model is introduced within the framework of conventional layered shell elements, which can be easily implemented in commonly used FE packages, e.g. ETABS and SAP2000. In this model, the URM shell element comprises three layers accounting for cohesion and axial-frictional behaviour parallel and perpendicular to the bed joints, where the mechanical properties can be adjusted for various masonry configurations. The performance of the proposed model is validated against several experimental tests available in the literature, where a good correlation with test data is achieved across various design scenarios and loading conditions.
[1] A. M. D’Altri et al., “Modeling Strategies for the Computational Analysis of Unreinforced Masonry Structures: Review and Classification,” Arch. Comput. Methods Eng., vol. 27, no. 4, pp. 1153–1185, Sep. 2020.
[2] A. PAGE, “THE BIAXIAL COMPRESSIVE STRENGTH OF BRICK MASONRY.,” Proc. Inst. Civ. Eng., vol. 71, no. 3, pp. 893–906, Sep. 1981.
[3] K. Beyer, “Peak and residual strengths of brick masonry spandrels,” Eng. Struct., vol. 41, pp. 533–547, 2012.
[4] J. van Elk and D. Doornhof, “Material Characterisation Version 1.3 Report,” 2016.
[5] J. A. Thamboo, “Material characterisation of thin layer mortared clay masonry,” Constr. Build. Mater., vol. 230, p. 116932, 2020.
[6] T. Manzouri, M. P. Schuller, P. B. Shing, and B. Amadei, “Repair and retrofit of unreinforced masonry structures,” Earthquake Spectra, vol. 12, no. 4. pp. 903–922, 1996.
[7] L. S. Hogan, I. Giongo, K. Q. Walsh, J. M. Ingham, and D. Dizhur, “Full-scale Experimental Pushover Testing of an Existing URM Building,” Structures, vol. 15, no. March, pp. 66–81, 2018.
[8] M. Tondelli, M. Rota, A. Penna, and G. Magenes, “Evaluation of Uncertainties in the Seismic Assessment of Existing Masonry Buildings,” J. Earthq. Eng., vol. 16, no. sup1, pp. 36–64, Jan. 2012.
[9] A. M. D’Altri, F. Messali, J. Rots, G. Castellazzi, and S. de Miranda, “A damaging block- based model for the analysis of the cyclic behaviour of full-scale masonry structures,” Eng. Fract. Mech., vol. 209, pp. 423–448, Mar. 2019.
[10] E. Minga, L. Macorini, and B. A. Izzuddin, “A 3D mesoscale damage-plasticity approach for masonry structures under cyclic loading,” Meccanica, vol. 53, no. 7, pp. 1591–1611, May 2018.
[11] G. Maier and A. Nappi, “A theory of no-tension discretized structural systems,” Eng. Struct., vol. 12, no. 4, pp. 227–234, Oct. 1990.
[12] D. Briccola, M. Bruggi, and A. Taliercio, “Analysis of 3D no-tension masonry-like walls,” J. Mech. Mater. Struct., vol. 13, no. 5, pp. 631–646, Dec. 2018.
[13] H. R. Lotfi and P. B. Shing, “An appraisal of smeared crack models for masonry shear wall analysis,” Comput. Struct., vol. 41, no. 3, pp. 413–425, Jan. 1991.
[14] J. Toti, V. Gattulli, and E. Sacco, “Nonlocal damage propagation in the dynamics of masonry elements,” Comput. Struct., vol. 152, pp. 215–227, May 2015.
[15] P. B. Lourenço, Computational strategies for masonry structures, vol. 70, no. 08. 1996.
[16] T. Salonikios, C. Karakostas, V. Lekidis, and A. Anthoine, “Comparative inelastic pushover analysis of masonry frames,” Eng. Struct., vol. 25, no. 12, pp. 1515–1523, 2003.
[17] R. Siano et al., “Numerical investigation of non-linear equivalent-frame models for regular masonry walls,” Eng. Struct., vol. 173, no. June, pp. 512–529, 2018.
[18] CSI, “ETABS Analysis and Design of Building Systems.” Computers and Structures Inc, Berkeley, California.
[19] CSI, “SAP2000 Integrated Software for Structural Analysis and Design.” Computers and Structures Inc, Berkeley, California.
[20] J. Heyman, “The stone skeleton,” Int. J. Solids Struct., vol. 2, no. 2, pp. 249–279, Apr. 1966.
[21] K. Doherty, M. C. Griffith, N. Lam, and J. Wilson, “Displacement-based seismic analysis for out-of-plane bending of unreinforced masonry walls,” Earthq. Eng. Struct. Dyn., vol. 31, no. 4, pp. 833–850, 2002.
[22] Federal Emergency Management Agency, “FEMA 440 Improvement of Nonlinear Static Seismic Analysis Procedures,” Redwood City, CA, 2005.
[23] ASCE, Seismic Evaluation and Retrofit of Existing Buildings ASCE/SEI 41-17. 2017.
[24] NZSEE, The Seismic Assessment of Existing Buildings - Initial Seismic Assessment Part B. 2017.
[25] D. J. Sutcliffe, H. S. Yu, and A. W. Page, “Lower bound limit analysis of unreinforced masonry shear walls,” Comput. Struct., vol. 79, no. 14, pp. 1295–1312, Jun. 2001.
[26] K. Chaimoon and M. M. Attard, “Modeling of unreinforced masonry walls under shear and compression,” Eng. Struct., vol. 29, no. 9, pp. 2056–2068, Sep. 2007.
[27] European Committee for Standardization, “Eurocode 6: Design of masonry structures - Part 1-1: General rules for reinforced and unreinforced masonry structures.” 2005.
[28] G. Giardina, A. Marini, M. A. N. Hendriks, J. G. Rots, F. Rizzardini, and E. Giuriani, “Experimental analysis of a masonry façade subject to tunnelling-induced settlement,” Eng. Struct., vol. 45, pp. 421–434, 2012.
[29] G. Giardina, A. V. van de Graaf, M. A. N. Hendriks, J. G. Rots, and A. Marini, “Numerical analysis of a masonry façade subject to tunnelling-induced settlements,” Eng. Struct., vol. 54, pp. 234–247, 2013.
[30] G. Magenes, G. M. Calvi, and G. R. Kingsley, “Seismic testing of a full-scale, two-storey masonry building: Test procedure and measured experimental response,” Exp. Numer. Investig. a brick Mason. Build. - Numer. Predict. Exp. Rep. 3.0 - G.N.D.T., no. January, pp. 1.1-1.41, 1995.
Published on 29/11/21
Submitted on 29/11/21
Volume Numerical modeling and structural analysis, 2021
DOI: 10.23967/sahc.2021.016
Licence: CC BY-NC-SA license
Are you one of the authors of this document?